Clinical Oral Investigations · 11 Nov 2026
Comparison of cone beam computed tomography measurements obtained after manual and AI-assisted head positioning and reconstruction
Bruno Werlangh-index 0, Débora Costa Ruiz, Amanda Flor, Monikelly do Carmo Chagas Nascimento, Anne Caroline Oenningh-index 15
Citations by database
Each database indexes a different set of journals, preprints and books, so they are shown side by side rather than blended.
- OpenCitations0
- Crossref0
- Europe PMC0
Citations per year
The current year is still counting.
- 2026 so far0
Abstract
Abstract Objectives To compare measurements obtained from cone beam computed tomography (CBCT) exams by radiologists following manual head positioning and panoramic curve tracing with those obtained after artificial intelligence (AI)-assisted positioning adjustments performed prior to measurement. Materials and methods Twenty-five CBCT exams presenting edentulous sites corresponding to missing mandibular first molars were selected. Five examiners performed measurements of bone height and width after manual head positioning adjustments and panoramic curve tracing (manual method). Subsequently, the same exams were processed using TomoNav software, which automatically performed volume alignment and generated the panoramic curve and cross-sectional images. The examiners then repeated the measurements (AI-assisted method). Measurements obtained from both approaches were summarized using descriptive statistics and compared using the intraclass correlation coefficient (ICC), paired t-test, and Bland–Altman analysis (p˂0.05). Results Excellent inter-examiner reproducibility was observed for both height and width measurements, with ICC values of 0.94 for height and 0.81 and 0.85 for width using the manual and AI-assisted methods, respectively. Significant differences were identified for left-side height, total height, right-side width, and total width ( p < 0.05). However, the mean biases were low and overall agreement between methods was excellent, with ICC values equal or greater than 0.89. Conclusion Measurements obtained with the AI-assisted method for volume repositioning and generation of panoramic and cross-sectional images were comparable to those obtained using a conventional method. Clinical relevance AI facilitates CBCT implant-planning preprocessing without compromising measurement reproducibility.
What the data shows
- No database records a citation yet, as is usual for a paper this new.
- Anne Caroline Oenning has the highest h-index among the authors (15).
Graph
This paper in the middle, its authors and their most-cited papers below, the papers it cites to the left and the papers citing it to the right. The timeline lays every paper out by year.
Select a node for its details. Drag to pan, scroll to zoom, drag a node to move it.
Start with
Cited by 0 papers
Who cites this paper, from open citation data, with Crossref's record of each; the 100 newest when there are more.
References (33)
What it cites, from open citation data, with Crossref's record of each.
Sign in to see 13 more references
A free account opens the rest of the citing papers and references on every paper’s page.