Journal of Imaging Informatics in Medicine · 17 Nov 2026
A Deep Learning Framework for Retrospective Motion Detection and Conditional Correction (MDCC): Application to Multi-Gradient-Recalled Echo Quantitative MRI
Gulfam Ahmed Sajuh-index 4, Jeramy Lewis, Satya V. V. N. Kothapalli, Cihat Eldeniz, Dmitriy A. Yablonskiyh-index 52
Citations by database
Each database indexes a different set of journals, preprints and books, so they are shown side by side rather than blended.
- OpenCitations0
- Crossref0
- Europe PMC0
Citations per year
The current year is still counting.
- 2026 so far0
Abstract
Abstract Multi-echo gradient-recalled-echo (mGRE) MRI supports quantitative neuroimaging by enabling voxel-wise T2*/R2*/R2t* mapping for quantitative assessment of tissue damage and magnetic susceptibility imaging. Subject motion degrades these acquisitions by introducing inconsistencies due to phase-encoding steps collected at different head positions. Although the gradient echoes associated with a given phase-encoding line are acquired at practically the same head position, differences in contrast, signal-to-noise ratio, and B0 field-dependent phase evolution cause the resulting artifacts to appear differently across echoes and can bias downstream parametric maps. Existing learning-based retrospective correction approaches often discard complex phase information, treat multiple gradient-recalled echoes independently, and apply correction indiscriminately to both motion-corrupted and clean data. We propose Motion Detection and Conditional Correction (MDCC), a retrospective image-domain pipeline that couples a complex-input volume-level Multi-Echo Motion Detection (ME-MoD) model and a complex-valued Multi-Echo Motion Corrector (ME-MoC) in an iterative detect–correct–re-evaluate loop, where correction is invoked only on volumes flagged as motion corrupted. ME-MoD reweights each echo with a phase-preserving paired complex gate, followed by a shared residual slice encoder, and a selected volume-level aggregator. ME-MoC is a fully complex-valued, factorized U-Net with echo-axis multi-head self-attention at the bottleneck, trained with a T2*-consistency physics loss. ME-MoD attained an AUC of 0.95 and sensitivity of 0.91 on the held-out detection set. At the cohort-level analysis, ME-MoC improved downstream R2* fitting results relative to the motion-corrupted input and 2D U-Net and achieved the lowest numerical R2* root-mean-square error (RMSE) among the evaluated methods, including modest numerical improvement over baseline.
What the data shows
- No database records a citation yet, as is usual for a paper this new.
- Dmitriy A. Yablonskiy has the highest h-index among the authors (52).
Graph
This paper in the middle, its authors and their most-cited papers below, the papers it cites to the left and the papers citing it to the right. The timeline lays every paper out by year.
Select a node for its details. Drag to pan, scroll to zoom, drag a node to move it.
Start with
Cited by 0 papers
Who cites this paper, from open citation data, with Crossref's record of each; the 100 newest when there are more.
References (54)
What it cites, from open citation data, with Crossref's record of each.
Sign in to see 34 more references
A free account opens the rest of the citing papers and references on every paper’s page.