Journal of General Internal Medicine · 17 Nov 2026
Comparative Diagnostic Accuracy of Point-of-Care Ultrasound for Detecting Reduced Left Ventricular Systolic Function: A Systematic Review and Meta-Analysis
Misha A. Khan, Richard A. Shellenberger, Ian R. Ross, Yash B. Patel, Alycia C. Bellino, Mohammed El Nayir, Karldon I. Nwaezeapu, Emmanuel Daniel, Paul Zamarripa, Sichao Wang, Woo J. Moonh-index 2
Citations by database
Each database indexes a different set of journals, preprints and books, so they are shown side by side rather than blended.
- OpenCitations0
- Crossref0
- Europe PMC0
Citations per year
The current year is still counting.
- 2026 so far0
Abstract
Abstract Objective To assess the diagnostic accuracy of point-of-care ultrasound (POCUS) for detecting reduced left ventricular systolic function (LVSF) using visual qualitative assessment (VQA), E-point septal separation (EPSS), and artificial intelligence (AI)-assisted assessment, compared with transthoracic echocardiography (TTE). Methods We searched PubMed, Ovid MEDLINE, Embase, and the Cochrane Library from January 1, 1985, through July 8, 2025. Eligible studies compared POCUS-assessed LVSF with left ventricular ejection fraction measured by TTE (or cardiac MRI in one study). Data were pooled using random-effects meta-analysis to determine the diagnostic odds ratio (DOR) and likelihood ratios (LR) for each of the three methods. Results Twenty-eight studies, including 4,647 participants, met inclusion criteria. Nine studies evaluating VQA yielded a DOR of 40.53 (95% CI, 15.07 to 109.00; P < 0.001) and a positive LR (LR + ) of 6.90 (95% CI, 3.75 to 12.69). Seven studies evaluating EPSS resulted in a DOR of 21.77 (95% CI, 10.25 to 46.28; P < 0.001) and a LR + of 5.70 (95% CI, 2.89 to 11.22). Five studies evaluating AI-assisted POCUS resulted in a DOR of 47.35 (95% CI, 16.87 to 132.93; P < 0.001) and a LR + of 8.37 (95% CI, 4.40 to 15.93). Meta-regression analyses revealed no statistically significant differences in diagnostic performance among the three methods. Subgroup analysis by operator experience level also showed no statistically significant difference between novice and experienced operators for each method. Conclusions VQA, EPSS, and AI-assisted POCUS all demonstrate moderate-to-high diagnostic accuracy for identifying reduced LVSF, with no significant differences among methods on meta-regression or by operator experience level. Moderately strong LR + across all three methods supports the use of POCUS for ruling in reduced LVSF. EPSS cutoffs at the lower and upper ends of the reported range showed higher sensitivity and specificity, respectively, suggesting utility as a rule-in or rule-out tool where formal echocardiography is not readily available. Registration PROSPERO CRD42024626542.
What the data shows
- No database records a citation yet, as is usual for a paper this new.
- Woo J. Moon has the highest h-index among the authors (2).
Graph
This paper in the middle, its authors and their most-cited papers below, the papers it cites to the left and the papers citing it to the right. The timeline lays every paper out by year.
Select a node for its details. Drag to pan, scroll to zoom, drag a node to move it.
Start with
Cited by 0 papers
Who cites this paper, from open citation data, with Crossref's record of each; the 100 newest when there are more.
References (62)
What it cites, from open citation data, with Crossref's record of each.
Sign in to see 42 more references
A free account opens the rest of the citing papers and references on every paper’s page.