Scientific Reports · 13 Nov 2026
SQCDL-WIoT: a scalable quantum convolutional deep learning framework with wearable IoT integration for breast cancer screening
Kama Ramudu, Swapna Saturi, Boddu Ramadevi, Nainavarapu Radha, H. K. Prasad Katamreddi, Anju Susan George, Stuti Pandey
Citations by database
Each database indexes a different set of journals, preprints and books, so they are shown side by side rather than blended.
- OpenCitations0
- Crossref0
Citations per year
The current year is still counting.
- 2026 so far0
Abstract
Abstract Deep learning techniques have greatly improved the ability to perform automatic diagnosis of breast cancer through use of computers; however, existing techniques are generally complex and costly, do not well incorporate multiple data modalities, and cannot be deployed clinically in real time. This paper proposes SQCDL-WIoT, which is a scalable, wearable-based internet of things (IoT)-enabled quantum convolutional deep learning (C-DL) framework capable of multi-class breast cancer screening. The proposed method includes two VQCs with five qubits each that can be embedded into a ResNet-50 back bone. In addition to being able to process images from histopathology and wearable-based bio sensor signals as input, the method also enables the incorporation of both wearable based bio sensor signal processing (i.e., wearable-IoT) and clinical variables via the Squeeze-and-Excitation (SE) attention mechanism. Thus, this proposed method is capable of hybrid quantum-classical training. Using stratified k-folds cross-validation (where k = 5) on the BreaKHis dataset and zero-shot transfer learning on the CBIS-DDSM dataset, SQCDL-WIoT demonstrated the highest accuracy (98.14%) with the highest sensitivity (macro-sensitivity = 97.63%), specificity (macro-specificity = 98.87%), and area under curve (AUC = 0.9891) when compared to all other baseline methods at 40x magnification on BreaKHis. Additionally, SQCDL-WIoT demonstrated 93.41% accuracy on the CBIS-DDSM dataset via zero shot learning, indicating good cross-domain generalization. Finally, the wearable IoT sub-system demonstrated a mean real-time edge-inference latency of 378 ± 12 milliseconds on an ARM Cortex-A72 processor, meeting the defined clinical threshold for response of < 400 milliseconds. The results of ablation studies indicated that both quantum convolution and SE attention contributed to complementary and synergetic increases in performance compared to classical ResNet-50 baseline models. Overall, the collective results presented here indicate that the proposed hybrid quantum-classical DL framework combined with wearable-based IoT sensing may represent a viable solution to scalable and intelligent breast cancer screening.
What the data shows
- No database records a citation yet, as is usual for a paper this new.
Graph
This paper in the middle, its authors and their most-cited papers below, the papers it cites to the left and the papers citing it to the right. The timeline lays every paper out by year.
Select a node for its details. Drag to pan, scroll to zoom, drag a node to move it.
Start with
Cited by 0 papers
Who cites this paper, from open citation data, with Crossref's record of each; the 100 newest when there are more.
References (0)
What it cites, from open citation data, with Crossref's record of each.