Review of Scientific Instruments · 1 Nov 2026
Impact of instrumental effects and target thickness on the SPARC magnetic proton recoil spectrometer response function
M. Dalla Rosa, D. Rigamonti, S. Mackie, M. Nocente, B. I. Buschmann, J. Carmichael, J. Kunimune, S. Fugazza, S. Colombi, A. Dal Molin, E. Gallo, G. Gorini, D. Kelley, M. H. Kushoro, M. Gatu Johnson, M. Litchfield, G. Marcer, E. Panontin, M. Parisi, E. Perelli Cippo, P. Raj, M. Rebai, M. Reinke, A. Seltzmanh-index 10, F. Scioscioli, S. Shubin, L. Silvestrin, M. Tessaro, L. G. Tedoldi, R. A. Tinguelyh-index 20, M. Tunesi, S. Vanellone, K. B. Woller, R. Woltjer, M. Tardocchih-index 51
Citations by database
Each database indexes a different set of journals, preprints and books, so they are shown side by side rather than blended.
- OpenCitations0
- Crossref0
- Europe PMC0
Citations per year
The current year is still counting.
- 2026 so far0
Abstract
The SPARC tokamak aims to demonstrate net fusion power gain in tokamaks (Q-fus > 1). To measure neutron emission, a neutron spectrometer based on the magnetic proton recoil technique is being developed. This diagnostic operates by converting collimated neutrons into recoil protons through elastic scattering on a polyethylene target. The recoiled protons are then separated based on their momentum by a magnetic field and subsequently detected by a hodoscope composed of plastic scintillation detectors coupled to photomultiplier tubes. This allows neutron energies in the 2–20 MeV range to be discriminated, though only neutrons in a narrower energy window (±25% around the selected central energy) can be measured. The instrument will contribute to the determination of the total fusion power and provide information on plasma parameters such as ion temperature and the presence of non-thermal fuel ions. In this study, the design rationale of the hodoscope is presented and the main instrumental effects that govern proton collection are characterized. The hodoscope is divided into three regions with different channel widths, depths, and lengths, jointly optimized to satisfy three coupled physical requirements: sufficient energy resolution at the 14.1 MeV DT peak, full proton containment up to 18.75 MeV, and limitation of the background through minimization of the detector volume. Three correction factors are evaluated through dedicated simulations: the vertical signal loss due to protons falling outside the scintillator rod length, the cross-talk between adjacent channels, and the background contribution per channel. A correction scheme combining all three factors is presented.
What the data shows
- No database records a citation yet, as is usual for a paper this new.
- M. Tardocchi has the highest h-index among the authors (51).
Graph
This paper in the middle, its authors and their most-cited papers below, the papers it cites to the left and the papers citing it to the right. The timeline lays every paper out by year.
Select a node for its details. Drag to pan, scroll to zoom, drag a node to move it.
Start with
Cited by 0 papers
Who cites this paper, from open citation data, with Crossref's record of each; the 100 newest when there are more.
References (17)
What it cites, from open citation data, with Crossref's record of each.