OpenResearchAlpha

Review of Scientific Instruments · 1 Nov 2026

Design and characterization of the magnetic proton recoil neutron spectrometer for burning plasma studies on SPARC (invited)

S. Mackie, M. Dalla Rosa, C. W. Wink, J. L. Ball, J. Carmichael, D. Kelley, D. Rigamonti, M. Tardocchih-index 51, G. P. A. Berg, V. R. Allamraju, J. Eriksson, J. van de Lindt, C. Perks, J. Wright, J. E. Rice, J. Frenjeh-index 66, P. Raj, R. A. Tinguelyh-index 20

0
Citations
no database records one yet
0
Citations in 2026
so far
66
Leading author's h-index
J. Frenje, in QAI's scholar index
46
References
works it cites, from open citation data

Citations by database

Each database indexes a different set of journals, preprints and books, so they are shown side by side rather than blended.

  • OpenCitations0
  • Crossref0
  • Europe PMC0

Citations per year

The current year is still counting.

  • 2026 so far0

Abstract

The SPARC tokamak is expected to robustly enter the burning plasma regime (Q > 5) during deuterium–tritium operations and will provide a unique platform to study novel effects of alpha heating in reactor-relevant plasma scenarios. This article presents the near-final design and characterization of the high-resolution magnetic proton recoil (MPR) neutron spectrometer for SPARC and discusses the opportunities for burning plasma studies enabled by this instrument. The MPR spectrometer will be positioned in the midplane line of sight of the poloidal neutron camera and view SPARC’s core plasma. The as-built instrumental response function is calculated based on measured magnetic fields, which have been optimized to maximize resolution and sensitivity constrained by limited space and power. The spectrometer has variable resolution and sensitivity, with settings ranging from high efficiency (2.22 × 10−6 counts per incident neutron) and low resolution (1070 keV) to low efficiency (1.48 × 10−7 counts per incident neutron) and high resolution (149 keV). We also present kinetic simulations of burning plasma effects, which we use to calculate synthetic neutron spectra to better understand the diagnostic capabilities of the instrument. Based on these simulations, the spectrometer is expected to diagnose core ion temperature with less than 7% uncertainty and time resolution less than 100 ms in break-even campaign experiments. Non-thermal alpha knock-on fusion is found to be a small contribution to overall fusion power; however, it does produce a measurable feature in the neutron spectrum that can be used to evaluate alpha heating and confinement in high-gain scenarios.

What the data shows

  • No database records a citation yet, as is usual for a paper this new.
  • J. Frenje has the highest h-index among the authors (66).

Graph

This paper in the middle, its authors and their most-cited papers below, the papers it cites to the left and the papers citing it to the right. The timeline lays every paper out by year.

Citing paper shares an authorAuthor without a profileSize shows citations, or h-index for authors

Select a node for its details. Drag to pan, scroll to zoom, drag a node to move it.

Start with

Authors (18)

Each author's standing in QAI's scholar index: the works their ORCID iD is attached to, and for anyone whose ORCID record names a lab OpenResearch follows, their arXiv preprints matched by name and a shared co-author. Names are as printed on the paper.

ProfileMost-cited paper

Cited by 0 papers

Who cites this paper, from open citation data, with Crossref's record of each; the 100 newest when there are more.

0 shown
No citing papers for this filter.

References (46)

What it cites, from open citation data, with Crossref's record of each.

COSY INFINITY Version 9
Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment · 2006
239

Sign in to see 26 more references

A free account opens the rest of the citing papers and references on every paper’s page.