OpenTOPAS-SPECT: an extension for full-physics clinical and preclinical SPECT simulation
Victor V Onechah-index 6, Alejandro Bertoleth-index 15
Citations by database
Each database indexes a different set of journals, preprints and books, so they are shown side by side rather than blended.
- OpenCitations0
- Crossref0
Citations per year
The current year is still counting.
- 2026 so far0
Abstract
Abstract Objective. Single-photon emission computed tomography (SPECT) simulations must resolve collimator transport, detector energy deposition, and low-efficiency projection formation within one model. General transport codes leave users to build the imaging components, whereas dedicated SPECT codes offer efficient camera models with less freedom to represent new systems. We developed OpenTOPAS-SPECT to bring projection-domain SPECT simulation into the declarative parameter-file workflow of OpenTOPAS. Approach. We added parametric parallel-hole, converging, pinhole, multi-pinhole, and slit-slat collimators; sodium-iodide and cadmium-zinc-telluride detector configurations; energy-resolved and forced-detection scorers; native decay-chain sources; and an evidence-graded library of 14 camera presets. We tested preset construction, multi-view consistency, and variance reduction, and benchmarked projection-domain quantities against measured, independent-code, and analytic references. Main results. At 140.5 keV and 10 cm from the collimator face, the Siemens Symbia low-energy high-resolution (LEHR) configuration gave 7.49 × 10 −5 counts per decay, or 0.82 of the measured 9.1 × 10 −5 . GE collimator sensitivities were 1.08–1.15× the SIMIND range midpoints, while the 364.5 keV low-to-high-energy sensitivity ratio was 59.5 versus 67.7. Planar point-spread widths were 4%–9% below analytic geometric resolution from 5 to 30 cm. In this Symbia LEHR point-source geometry, forced detection reached matched precision 6.9× faster than full transport and reproduced its absolute sensitivity to 1% without calibration. Across 20 configurations (five collimators, 113 keV–1 MeV), forced detection stayed within 4% of full transport while septa carried up to a fifth of the signal, but fell 7% to 25% below it where they carried 25% or more. The release-gating suite ran all 23 example decks and built all 14 presets. Significance. OpenTOPAS-SPECT provides reusable SPECT components within the OpenTOPAS parameter system, with bounded projection-domain benchmarks for the first stable public release. The evidence supports the tested configurations and observables; reconstructed-image accuracy and broader system coverage remain untested.
What the data shows
- No database records a citation yet, as is usual for a paper this new.
- Alejandro Bertolet has the highest h-index among the authors (15).
Graph
This paper in the middle, its authors and their most-cited papers below, the papers it cites to the left and the papers citing it to the right. The timeline lays every paper out by year.
Select a node for its details. Drag to pan, scroll to zoom, drag a node to move it.
Start with
Cited by 0 papers
Who cites this paper, from open citation data, with Crossref's record of each; the 100 newest when there are more.
References (28)
What it cites, from open citation data, with Crossref's record of each.
Sign in to see 8 more references
A free account opens the rest of the citing papers and references on every paper’s page.