Anesthesiology · 5 Nov 2026
Frequency of Adherence to Obstetric Anesthesia Best Practices for Cesarean Delivery: A Multicenter Retrospective Cohort Analysis
Jordan A. Franckeh-index 1, David Stein, Brandon M. Togioka, Thomas T. Klumpner, Michael J. Furdyna, Brendan Carvalho, Brian T. Bateman, Sharon C. Realeh-index 9
Citations by database
Each database indexes a different set of journals, preprints and books, so they are shown side by side rather than blended.
- OpenCitations0
- Crossref0
Citations per year
The current year is still counting.
- 2026 so far0
Abstract
Background: Increasingly, protocols have been developed to optimize obstetric anesthesia care. However, there is a paucity of data on adherence to these guidelines. The primary aims of this study were to utilize the Multicenter Perioperative Outcomes Group (MPOG) database to estimate (1) the rate of adherence to best practice guidelines for cesarean delivery, (2) the association of case- and hospital-level factors with adherence, and (3) the percentage of variability in adherence attributable to the patient-, case-, and hospital-level factors. Methods: The authors performed a multicenter observational cohort study utilizing the MPOG database to review all cesarean deliveries in women age 15 to 44 yr. Best practices were defined based on societal guidelines and included timely antibiotic administration, postspinal systolic blood pressure (SBP) maintenance greater than 90 mmHg, general anesthesia avoidance, prevention of perioperative hypothermia, use of low-dose neuraxial morphine, postspinal vasopressor infusions, and spinal needles 25-gauge or smaller. Covariates of interest included patient-, case-, and hospital-level factors. Results: The authors analyzed 289,047 cesarean delivery cases in the MPOG database from 2015 to 2022. The following adherence outcomes were observed: timely antibiotic administration, 86.2% (99% CI, 86 to 86.3%); postspinal SBP maintenance, 96.7% (99% CI, 96.6 to 96.8%); avoidance of general anesthesia, 97.0% (99% CI, 96.9 to 97.0%); prevention of perioperative hypothermia, 56.7% (99% CI, 56.5 to 56.9%); use of low-dose neuraxial morphine, 74.2% (99% CI, 74.0 to 74.5%); use of postspinal vasopressor infusion, 55.4% (99% CI, 55.1 to 55.8%); and use of 25-gauge needle or smaller for spinal anesthesia, 89.0% (99% CI, 88.6 to 89.4%). Poorer adherence correlated with factors at the patient level (American Society of Anesthesiologists [Schaumburg, Illinois] Physical Status IV or greater), case level (evening or overnight cesarean delivery), and institution level (absence of obstetric fellowship or Center of Excellence status). Conclusions: Among this large cohort of cesarean delivery cases, overall adherence to guideline-supported best practices was variable, with postspinal vasopressor infusions being the lowest and avoidance of general anesthesia being the highest. Targeted interventions addressing these factors may improve quality and promote more optimal care.
What the data shows
- No database records a citation yet, as is usual for a paper this new.
- Sharon C. Reale has the highest h-index among the authors (9).
Graph
This paper in the middle, its authors and their most-cited papers below, the papers it cites to the left and the papers citing it to the right. The timeline lays every paper out by year.
Select a node for its details. Drag to pan, scroll to zoom, drag a node to move it.
Start with
Cited by 0 papers
Who cites this paper, from open citation data, with Crossref's record of each; the 100 newest when there are more.
References (17)
What it cites, from open citation data, with Crossref's record of each.