OpenResearchAlpha

Plastic and Reconstructive Surgery - Global Open · 12 Nov 2026

Scalpel Versus Geometric Electron Modulation Electrocautery in Thyroid and Parathyroid Surgery: A Randomized Controlled Trial

Tanatcha Pojkhamkam, Varut Supanakorn, Worawat Rawangban, Napadon Tangjaturonrasme, Wisarut Samuckkeethum

0
Citations
no database records one yet
0
Citations in 2026
so far
–
Leading author's h-index
no author has a profile yet
18
References
works it cites, from open citation data

Citations by database

Each database indexes a different set of journals, preprints and books, so they are shown side by side rather than blended.

  • OpenCitations0
  • Crossref0
  • Europe PMC0

Citations per year

The current year is still counting.

  • 2026 so far0

Abstract

Background: Postoperative scarring is an important concern following thyroid and parathyroid surgery. Geometric electron modulation (GEM) electrocautery is designed to reduce tissue injury while providing effective hemostasis. However, evidence regarding its long-term cosmetic outcomes remains limited. This study compares long-term scar quality following cervical incisions created using GEM electrocautery versus a conventional scalpel. Methods: In this prospective, randomized, self-controlled trial, 24 patients undergoing thyroidectomy or parathyroidectomy were enrolled. Each half of the cervical incision was randomly assigned to GEM electrocautery or conventional scalpel. Intraoperative blood loss, incision time, and surgical field clarity were recorded. Scar quality was assessed at 2 weeks and at 1, 3, and 12 months using the Thai linear version of the Patient and Observer Scar Assessment Scale. Longitudinal analyses were performed using generalized estimating equations. Results: Patient-reported Patient and Observer Scar Assessment Scale scores were significantly lower in the GEM group at 1 month ( P = 0.02), with no differences at other follow-up visits. Observer-reported scores did not differ significantly at any time point. Longitudinal analyses demonstrated no significant differences in patient- or observer-reported scar outcomes between groups (generalized estimating equation P = 0.69 and 0.67, respectively). GEM electrocautery was associated with lower measured blood loss and a shorter incision time (both P < 0.01). Conclusions: GEM electrocautery and conventional scalpel incisions achieved comparable long-term scar outcomes. Although GEM was associated with modest improvements in intraoperative parameters, the clinical significance of these differences should be interpreted in the context of the higher cost of the device.

What the data shows

  • No database records a citation yet, as is usual for a paper this new.

Graph

This paper in the middle, its authors and their most-cited papers below, the papers it cites to the left and the papers citing it to the right. The timeline lays every paper out by year.

Citing paper shares an authorAuthor without a profileSize shows citations, or h-index for authors

Select a node for its details. Drag to pan, scroll to zoom, drag a node to move it.

Start with

Authors (5)

Each author's standing in QAI's scholar index: the works their ORCID iD is attached to, and for anyone whose ORCID record names a lab OpenResearch follows, their arXiv preprints matched by name and a shared co-author. Names are as printed on the paper.

ProfileMost-cited paper

Cited by 0 papers

Who cites this paper, from open citation data, with Crossref's record of each; the 100 newest when there are more.

0 shown
No citing papers for this filter.

References (18)

What it cites, from open citation data, with Crossref's record of each.