Annals of Plastic Surgery · 11 Nov 2026
Artificial Intelligence-Assisted Visual Mapping of Viable and Necrotic Tissue During Wound Debridement
Min Zhang, Feng Zhang, Liang Cheng, William C. Lineaweaver, Wei Kong, Gen Wen
Citations by database
Each database indexes a different set of journals, preprints and books, so they are shown side by side rather than blended.
- OpenCitations0
- Crossref0
- Europe PMC0
Citations per year
The current year is still counting.
- 2026 so far0
Abstract
Background: Accurate distinction between viable and necrotic tissue is essential during wound debridement, but visual assessment may be affected by blood coverage, uneven illumination, blurred tissue transitions, and instrument occlusion. This study developed and evaluated a deep learning-assisted image segmentation method for wound tissue assessment. Methods: A retrospective data set of clinical wound debridement images was annotated at the pixel level as background, viable or preservable tissue, and necrotic or nonviable tissue. Tissue-aware copy-paste augmentation was used to improve necrotic tissue representation. A SegFormer-based semantic segmentation model with boundary-aware output was trained and evaluated using pixel accuracy, intersection over union (IoU), Dice coefficient, precision, recall, and boundary F1 score. Results: The augmented data set contained 356 image-mask pairs, including 156 original and 200 synthesized pairs. Training, validation, and test sets included 249, 53, and 54 samples, respectively. On the test set, pixel accuracy was 98.01%. For viable and necrotic tissue, mean IoU and mean Dice were 85.97% and 92.45%, respectively. Dice scores were 92.24% for viable tissue and 92.67% for necrotic tissue. Necrotic tissue recall was 94.09%, and mean boundary F1 was 61.83%. Conclusions: The proposed method showed strong region-level agreement with expert annotations and high sensitivity for necrotic tissue. Color-coded prediction maps and overlay visualizations may support wound tissue assessment, although exact boundary localization remained less accurate. Larger independent clinical data sets are needed for further validation.
What the data shows
- No database records a citation yet, as is usual for a paper this new.
Graph
This paper in the middle, its authors and their most-cited papers below, the papers it cites to the left and the papers citing it to the right. The timeline lays every paper out by year.
Select a node for its details. Drag to pan, scroll to zoom, drag a node to move it.
Start with
Cited by 0 papers
Who cites this paper, from open citation data, with Crossref's record of each; the 100 newest when there are more.
References (19)
What it cites, from open citation data, with Crossref's record of each.