Journal of Clinical Neurophysiology · 11 Nov 2026
Artificial Intelligence-Based Neonatal Seizure Detection: A Pragmatic Evaluation of Clinical Performance Tradeoffs in Clinical EEG
Jennifer C. Keeneh-index 6, Nicholas S. Abend, Giulia M. Benedetti, Zach Fulmer, Maire Keene, Saeed Montazeri, Craig Press, Nathan J. Stevenson, Sampsa Vanhatalo, Amanda G. Sandoval Karamian
Citations by database
Each database indexes a different set of journals, preprints and books, so they are shown side by side rather than blended.
- OpenCitations0
- Crossref0
- Europe PMC0
Citations per year
The current year is still counting.
- 2026 so far0
Abstract
Purpose: The aim of this study was to evaluate how three artificial intelligence (AI)-based neonatal seizure detectors (NSDs) perform in a large, clinically acquired data set and their potential to support timely seizure identification. Methods: We conducted a secondary analysis of continuous EEG (cEEG) recordings from 169 neonates born at ≥35 weeks gestation with neonatal encephalopathy. Seizure presence was determined by independent review by two or three pediatric encephalographers, and 2,455 individual seizures were annotated by a single expert as a pragmatic, clinically representative reference standard. Three NSDs were evaluated: a feature-based support vector machine detector (NSD1) and two deep-learning detectors (NSD2 and Persyst-15). Using an any-overlap approach, outcomes included neonate-level seizure identification, seizure-level detection, false detections per day (FD/day), and detection latency. Results: We analyzed 15,343 hours of cEEG (median 98 hours per neonate); 55 neonates (33%) had seizures. All NSDs identified ≥95% of neonates with seizures. Seizure-level detection varied: NSD2 detected 35% (IQR 17–53%), NSD1 63% (IQR 38–82%), and Persyst-15 60% (IQR 37–80%) of seizures. NSD1 generated significantly more FDs (46 FD/day, IQR 22–82) than NSD2 (3.2 IQR 1.2–9.3) and Persyst-15 (2.8 IQR 1.1–6.2; P < 0.0001). The median time to first true detection was <1 minute for NSD1 and Persyst-15, versus 26 minutes for NSD2. Conclusions: AI-based NSDs demonstrated high infant-level sensitivity but different tradeoffs between seizure-level detection and alarm burden. These findings highlight how AI tools may augment clinical EEG workflows and support earlier seizure recognition, while underscoring the need for evaluation under real-world conditions to guide safe and effective implementation.
What the data shows
- No database records a citation yet, as is usual for a paper this new.
- Jennifer C. Keene has the highest h-index among the authors (6).
Graph
This paper in the middle, its authors and their most-cited papers below, the papers it cites to the left and the papers citing it to the right. The timeline lays every paper out by year.
Select a node for its details. Drag to pan, scroll to zoom, drag a node to move it.
Start with
Cited by 0 papers
Who cites this paper, from open citation data, with Crossref's record of each; the 100 newest when there are more.
References (31)
What it cites, from open citation data, with Crossref's record of each.
Sign in to see 11 more references
A free account opens the rest of the citing papers and references on every paper’s page.