Circulation: Cardiovascular Interventions · 13 Nov 2026
Impact of Coronary Sinus Reducer on the Extent of Ischemia in Functional Stress Tests
Sheizaf Gefenh-index 1, Gil Mashiah, Yoav Perez, Elina Stsiapanava, Miri Revivo, Haim Shmilovich, Shmuel Banai, Jeremy Ben-Shoshan, Maayan Konigsteinh-index 4
Citations by database
Each database indexes a different set of journals, preprints and books, so they are shown side by side rather than blended.
- OpenCitations0
- Crossref0
- Europe PMC0
Citations per year
The current year is still counting.
- 2026 so far0
Abstract
BACKGROUND: The coronary sinus reducer is an established therapy for patients with refractory angina due to obstructive coronary artery disease who are not candidates for further revascularization. Although symptomatic benefits are well documented, its effect on objective measures of ischemia remains unclear. This study aimed to evaluate the association between coronary sinus reducer implantation and inducible myocardial ischemia assessed by functional stress testing. METHODS: We retrospectively analyzed a prospectively maintained registry of consecutive patients undergoing coronary sinus reducer implantation between 2011 and 2024. Baseline assessment included Canadian Cardiovascular Society angina class, 6-minute walk test, stress echocardiography, and dipyridamole single-photon emission computed tomography imaging, repeated at 6 months. Coprimary outcomes were changes in stress wall motion score index and in the proportion of patients with moderate or severe ischemia on single-photon emission computed tomography. Clinical nonresponders were defined as no improvement in Canadian Cardiovascular Society class at 12 months. RESULTS: Among 153 treated patients, 118 had complete imaging data. Median stress wall motion score index improved from 1.38 to 1.23 ( P <0.001), and stress left ventricular ejection fraction increased from 55% to 60% ( P =0.019). The proportion of patients with moderate or severe ischemia on single-photon emission computed tomography decreased from 52% to 24% ( P <0.001). The summed difference score, available in 45 patients, did not change significantly. Clinically, 86% improved by ≥1 Canadian Cardiovascular Society class at 6 months. CONCLUSIONS: Coronary sinus reducer implantation was associated with reduced inducible ischemia on stress echocardiography and with clinical improvement. The proportion of patients with moderate or severe ischemia on single-photon emission computed tomography decreased following Reducer implantation.
What the data shows
- No database records a citation yet, as is usual for a paper this new.
- Maayan Konigstein has the highest h-index among the authors (4).
Graph
This paper in the middle, its authors and their most-cited papers below, the papers it cites to the left and the papers citing it to the right. The timeline lays every paper out by year.
Select a node for its details. Drag to pan, scroll to zoom, drag a node to move it.
Start with
Cited by 0 papers
Who cites this paper, from open citation data, with Crossref's record of each; the 100 newest when there are more.
References (32)
What it cites, from open citation data, with Crossref's record of each.
Sign in to see 12 more references
A free account opens the rest of the citing papers and references on every paper’s page.