OpenResearchAlpha

Journal of the American Heart Association · 18 Nov 2026

Standardized Ultrafast Transcranial Ultrasound Acquisition in Acute Stroke: The HYPER‐AI‐SCAN Pilot Study With Exploratory Artificial Intelligence Analysis

Renato Simonettih-index 3, Jesús David González Riveros, Pere Canals, Manuel Alanís‐Bernal, Julia Fernandez Martinez, Laia Boada Oller, Olalla Pancorbo, Noelia Rodriguez‐Villatoro, Ane Murillo‐Olaizola, Álvaro García‐Tornel, Marta Olivé‐Gadea, Federica Rizzo, Marián Muchada, Adriano Bonura, Nicoletta Brunelli, Giulio Fiore, João André Sousa, Umberto Pensato, Claudia Meza, Jorge Pagola, Marta Rubiera, Marc Ribó, Carlos A. Molina, David Rodriguez‐Lunah-index 41

0
Citations
no database records one yet
0
Citations in 2026
so far
41
Leading author's h-index
David Rodriguez‐Luna, in QAI's scholar index
16
References
works it cites, from open citation data

Citations by database

Each database indexes a different set of journals, preprints and books, so they are shown side by side rather than blended.

  • OpenCitations0
  • Crossref0

Citations per year

The current year is still counting.

  • 2026 so far0

Abstract

Background Intracerebral hemorrhage requires rapid mechanism‐specific treatment, yet early stroke triage relies on clinical severity scales that do not reliably distinguish hemorrhage from ischemic stroke. We assessed the feasibility of a standardized ultrafast transcranial ultrasound protocol designed to support subsequent artificial intelligence (AI)‐based intracerebral hemorrhage detection. Methods HYPER‐AI‐SCAN (Hyper‐Acute AI‐Assisted Sonographic Cerebral Hemorrhage Assessment Network) was a single‐center prospective feasibility study with embedded exploratory AI analysis. Between March and December 2025, 102 adults with acute computed tomography (CT)‐confirmed stroke were prospectively enrolled according to trained operator availability. Primary feasibility outcomes were protocol completion, operator‐rated adequate transtemporal windows, and acquisition time. In patients with retrievable paired baseline CT, exploratory AI analyses compared CT‐only, ultrasound‐only, and cross‐modal CT‐guided ultrasound models using patient‐level area under the receiver operating characteristic curve, sensitivity, and specificity. Results Two patients were excluded after acquisition because insonation depth was <19 cm, yielding 100 evaluable patients (33 intracerebral hemorrhage; 67 ischemic stroke). The protocol was completed in all evaluable patients; adequate transtemporal windows were identified in 87%, and median acquisition time was 22 seconds (interquartile range, 13–31). Paired baseline CT images were available in 91 patients. Mean area under the receiver operating characteristic curve was 0.86 (SD, 0.07) for the CT‐only model, 0.85 (SD, 0.14) for the ultrasound‐only model, and 0.92 (SD, 0.07) for the cross‐modal model. Conclusions Standardized ultrafast transcranial ultrasound acquisition was feasible at the bedside in acute stroke and generated brief cine‐loops suitable for exploratory AI development. Multicenter external validation is required before diagnostic or triage application. Registration Information Clinicaltrials.gov. Identifier: NCT07319013.

What the data shows

  • No database records a citation yet, as is usual for a paper this new.
  • David Rodriguez‐Luna has the highest h-index among the authors (41).

Graph

This paper in the middle, its authors and their most-cited papers below, the papers it cites to the left and the papers citing it to the right. The timeline lays every paper out by year.

Citing paper shares an authorAuthor without a profileSize shows citations, or h-index for authors

Select a node for its details. Drag to pan, scroll to zoom, drag a node to move it.

Start with

Authors (24)

Each author's standing in QAI's scholar index: the works their ORCID iD is attached to, and for anyone whose ORCID record names a lab OpenResearch follows, their arXiv preprints matched by name and a shared co-author. Names are as printed on the paper.

ProfileMost-cited paper

Cited by 0 papers

Who cites this paper, from open citation data, with Crossref's record of each; the 100 newest when there are more.

0 shown
No citing papers for this filter.

References (16)

What it cites, from open citation data, with Crossref's record of each.