OpenResearchAlpha

Surgical Innovation · 6 Nov 2026

Deep-Learning Enhanced Augmented Reality for Robotic Radical Prostatectomy on Consumer Grade Hardware

Vincent Benardh-index 0, Olivier Windisch, Mina Bjelogrlic, Hugues Turbé, Christian Lovis, Michele Diana, Massimo Valerio

0
Citations
no database records one yet
0
Citations in 2026
so far
0
Leading author's h-index
Vincent Benard, in QAI's scholar index
32
References
works it cites, from open citation data

Citations by database

Each database indexes a different set of journals, preprints and books, so they are shown side by side rather than blended.

  • OpenCitations0
  • Crossref0
  • Europe PMC0

Citations per year

The current year is still counting.

  • 2026 so far0

Abstract

Background Augmented Reality (AR) during Robotic-Assisted Radical Prostatectomy (RARP) provides surgical guidance by overlaying patient-specific 3D Virtual Models (VM) onto the intraoperative view. A main drawback is instrument occlusion, where VM overlaps the surgical tools, disturbing the augmented view. Deep learning (DL)-based desocclusion addresses this issue, but current implementation rely on expensive, specialized hardware. Methods We developed an AR desocclusion pipeline running on consumer-grade hardware (∼1150 US Dollars). For model selection, we trained and benchmarked 21 encoder architectures paired with a U-Net decoder. The selected model was integrated into a macOS application using CoreML inference on the Apple Neural Engine. Memory usage, thermal state and framerate were monitored on a continuous 81-minute console session. Photon-to-photon latency (from surgical field to the surgeon eye) was measured on the DaVinci® Xi using a microcontroller-phototransistor setup. Results FastViT-S12/Unet offered the highest accuracy among models meeting our inference-time budget (∼2 ms inference), achieving a Dice score of 95.1% (95% CI, 94.3-95.7) internally, 91.6% (95% CI, 90.2-92.9) and 90.2% (95% CI, 84.7-94.4) on externals tests, with a mean inference time of 1.89 ± 0.36 ms. The pipeline maintained 57.98 frames per second using 1.47 GB of unified memory with a nominal thermal state. On the surgical console, photon-to-photon median latency increased from 60 ms (Q1-Q3: 57.5-62.5) to 120.5 ms (Q1-Q3: 111-131) with the AR pipeline. Conclusions Real-time AR-RARP with DL-based desocclusion is achievable on low-cost hardware with an added latency remaining within ranges reported as technically acceptable for intraoperative use.

What the data shows

  • No database records a citation yet, as is usual for a paper this new.
  • Vincent Benard has the highest h-index among the authors (0).

Graph

This paper in the middle, its authors and their most-cited papers below, the papers it cites to the left and the papers citing it to the right. The timeline lays every paper out by year.

Citing paper shares an authorAuthor without a profileSize shows citations, or h-index for authors

Select a node for its details. Drag to pan, scroll to zoom, drag a node to move it.

Start with

Authors (7)

Each author's standing in QAI's scholar index: the works their ORCID iD is attached to, and for anyone whose ORCID record names a lab OpenResearch follows, their arXiv preprints matched by name and a shared co-author. Names are as printed on the paper.

ProfileMost-cited paper

Cited by 0 papers

Who cites this paper, from open citation data, with Crossref's record of each; the 100 newest when there are more.

0 shown
No citing papers for this filter.

References (32)

What it cites, from open citation data, with Crossref's record of each.

Sign in to see 12 more references

A free account opens the rest of the citing papers and references on every paper’s page.