OpenResearchAlpha

Global Spine Journal · 17 Nov 2026

Biomechanical Comparison of Composite versus Screw-Rod Fixation for Posterior C5-C6 Fusion

Harsh Wadhwah-index 12, Javier Castro, Calvin Chan, Somayeh H. Ahmad, Yun-Da Li, Serena S. Hu, Karl Bruckman, James M. Mokh-index 2

0
Citations
no database records one yet
0
Citations in 2026
so far
12
Leading author's h-index
Harsh Wadhwa, in QAI's scholar index
22
References
works it cites, from open citation data

Citations by database

Each database indexes a different set of journals, preprints and books, so they are shown side by side rather than blended.

  • OpenCitations0
  • Crossref0
  • Europe PMC0

Citations per year

The current year is still counting.

  • 2026 so far0

Abstract

Study Design Biomechanical. Objectives To compare subaxial cervical stability with a dental composite-plate construct versus lateral mass screw-rod construct. Methods 6 fresh-frozen human cadaveric cervical vertebrae (C4-C7) were prepared by stripping all soft tissues. Lateral mass screw fixation was performed bilaterally with standard freehand technique. Dental composite (Filtek) was applied to lamina before placement of a custom minifragment plate. Range of motion (ROM) and rotation to failure testing was performed using a robotic testing system (SimVITRO). Wilcoxon ranked sum test with Benjamini-Hochberg correction was used to compare results with significance set to p<0.05. Results The screw-rod construct (5.1±4.0 deg) and composite-plate construct (4.5±3.2 deg) significantly decreased flexion-extension ROM relative to native state (8.1±1.7 deg, p<0.05). Only the composite-plate construct (2.7±1.9 deg) significantly decreased lateral bending ROM relative to native state (4.7±2.5 deg, p<0.05). Both the screw-rod construct (7.0±4.3 deg) and composite-plate construct (5.7±3.7 deg) significantly decreased axial rotation ROM relative to native state (9.9±5.2 deg, p<0.05). Composite-plate also decreased axial rotation ROM relative to screw-rod, while both constructs had comparable ROM in flexion-extension and lateral bending. Flexion to failure for the composite-plate construct was 7.1 ± 1.7 N-m. Mechanism of failure was the composite cracking off bone. Conclusion Screw-rod and composite-plate constructs significantly decrease ROM compared to the native state and are comparable in stiffness. Failure of composite-plate occurs with composite cracking off undamaged bone surface. A strategy utilizing composite fixation may offer a reasonable alternative to screws for subaxial stabilization.

What the data shows

  • No database records a citation yet, as is usual for a paper this new.
  • Harsh Wadhwa has the highest h-index among the authors (12).

Graph

This paper in the middle, its authors and their most-cited papers below, the papers it cites to the left and the papers citing it to the right. The timeline lays every paper out by year.

Citing paper shares an authorAuthor without a profileSize shows citations, or h-index for authors

Select a node for its details. Drag to pan, scroll to zoom, drag a node to move it.

Start with

Authors (8)

Each author's standing in QAI's scholar index: the works their ORCID iD is attached to, and for anyone whose ORCID record names a lab OpenResearch follows, their arXiv preprints matched by name and a shared co-author. Names are as printed on the paper.

ProfileMost-cited paper

Cited by 0 papers

Who cites this paper, from open citation data, with Crossref's record of each; the 100 newest when there are more.

0 shown
No citing papers for this filter.

References (22)

What it cites, from open citation data, with Crossref's record of each.

Sign in to see 2 more references

A free account opens the rest of the citing papers and references on every paper’s page.

Biomechanical Comparison of Composite versus Screw-Rod Fixation for Posterior C5-C6 Fusion - QAI OpenResearch