OpenResearchAlpha

BMC Oral Health · 16 Nov 2026

Patient-specific three-dimensional titanium plate versus conventional two-miniplate fixation for mandibular angle fractures: a randomized clinical trial

Asmaa M. Abd Elfattahh-index 0, Mostafa M. Eldibany, Ragab S. Hassan, Mona S. Orabyh-index 2

0
Citations
no database records one yet
0
Citations in 2026
so far
2
Leading author's h-index
Mona S. Oraby, in QAI's scholar index
40
References
works it cites, from open citation data

Citations by database

Each database indexes a different set of journals, preprints and books, so they are shown side by side rather than blended.

  • OpenCitations0
  • Crossref0
  • Europe PMC0

Citations per year

The current year is still counting.

  • 2026 so far0

Abstract

Abstract Background Mandibular angle fractures are clinically challenging because of their anatomical complexity and biomechanical loading. Conventional two-miniplate fixation requires intraoperative plate adaptation and transbuccal instrumentation. Patient-specific three-dimensional titanium plates are designed to conform to individual mandibular anatomy and may facilitate intraoperative fixation. This study aimed to clinically and radiographically evaluate patient-specific three-dimensional titanium plate versus conventional two mini-plate fixation in the management of mandibular angle fractures. Methods Sixteen patients with recent mandibular angle fractures were randomly allocated into two equal groups ( n = 8). Group I underwent fixation using a patient-specific three-dimensional titanium plate positioned according to the preoperative virtual plan, whereas Group II received conventional two-miniplate fixation. The primary outcome was functional recovery assessed by maximal mouth opening (MMO). Secondary outcomes included intraoperative time, postoperative pain, facial edema, postoperative occlusion, wound healing, and CT bone density measurements in Hounsfield units (HU). Clinical outcomes were evaluated on postoperative days 1, 7, 14, and 30, whereas bone density was assessed immediately postoperatively and after 4 months. Results Intraoperative time was shorter in the patient-specific plate group than in the conventional two-miniplate group (40.00 ± 9.35 vs. 73.25 ± 11.22 min; P < 0.001). Postoperative pain was lower in the patient-specific plate group on postoperative day 1 ( P = 0.015), while facial edema was lower on postoperative days 1 ( P = 0.012) and 7 ( P = 0.031). No statistically significant between-group differences were detected in maximal mouth opening, postoperative occlusion, Landry wound healing index scores, or CT bone density at the four-month follow-up. One patient in each group developed wound dehiscence, with complete healing after conservative management. Conclusions Patient-specific three-dimensional titanium plate fixation was associated with shorter intraoperative time and lower early postoperative pain and edema. No statistically significant between-group differences were detected in the other assessed clinical and radiographic outcomes during the four-month follow-up. Trial registration The study was retrospectively registered at ClinicalTrials.gov (NCT07390734) on 29 January 2026.

What the data shows

  • No database records a citation yet, as is usual for a paper this new.
  • Mona S. Oraby has the highest h-index among the authors (2).

Graph

This paper in the middle, its authors and their most-cited papers below, the papers it cites to the left and the papers citing it to the right. The timeline lays every paper out by year.

Citing paper shares an authorAuthor without a profileSize shows citations, or h-index for authors

Select a node for its details. Drag to pan, scroll to zoom, drag a node to move it.

Start with

Authors (4)

Each author's standing in QAI's scholar index: the works their ORCID iD is attached to, and for anyone whose ORCID record names a lab OpenResearch follows, their arXiv preprints matched by name and a shared co-author. Names are as printed on the paper.

ProfileMost-cited paper

Cited by 0 papers

Who cites this paper, from open citation data, with Crossref's record of each; the 100 newest when there are more.

0 shown
No citing papers for this filter.

References (40)

What it cites, from open citation data, with Crossref's record of each.

Sign in to see 20 more references

A free account opens the rest of the citing papers and references on every paper’s page.