Simulation-guided design of exotendons to reduce the energetic cost of running
Jon Stingelh-index 3, Nicholas Bianco, Carmichael Ong, Steve Collins, Scott Delp, Jennifer Hicksh-index 38
Citations by database
Each database indexes a different set of journals, preprints and books, so they are shown side by side rather than blended.
- OpenCitations0
- Crossref0
- Europe PMC0
Citations per year
The current year is still counting.
- 2026 so far0
Abstract
A passive device that attaches to the feet, called an exotendon, can reduce the energetic cost of running at moderate speeds, but its efficacy and optimal design parameters at higher speeds are unknown. Identifying optimal parameters at new speeds experimentally would require many experimental trials with different exotendon designs, which is challenging for participants at higher running speeds. We developed a muscle-driven simulation framework to predict the effect of various exotendon designs on the energetic cost of running at an experimentally untested speed (4 m/s). We used these predictions to select four designs, which we evaluated experimentally as users ran at this speed. The framework correctly predicted that an exotendon that reduced energetic cost at 2.7 m/s would also reduce energetic cost at 4 m/s (10% predicted vs. 5.7% measured) and that a short, stiff exotendon and a long, compliant exotendon would not significantly reduce energetic cost. However, exotendon parameters predicted by the simulation to maximize energetic savings did not significantly reduce energetic cost when evaluated experimentally. There was variability between participants in both the magnitude of maximum energy savings and the exotendon condition associated with those savings. In a 5-km time trial performed with and without the exotendon condition that elicited the largest energy savings for each participant during the experiment, we observed a lower average heart rate (-3.9 ± 3.8 beats/min; P = 0.03; mean ± standard deviation) and increased cadence (15.9 ± 9.6 steps/min; P = 0.002) when participants ran with the exotendon but did not observe a statistically significant difference in finishing time (-13.5 ± 24.6 sec; P = 0.3). These results demonstrate exotendons can reduce energetic cost across multiple running speeds and that predictive simulations provide a framework for guiding experiments to evaluate assistive device designs.
What the data shows
- No database records a citation yet, as is usual for a paper this new.
- Jennifer Hicks has the highest h-index among the authors (38).
Graph
This paper in the middle, its authors and their most-cited papers below, the papers it cites to the left and the papers citing it to the right. The timeline lays every paper out by year.
Select a node for its details. Drag to pan, scroll to zoom, drag a node to move it.
Start with
Cited by 0 papers
Who cites this paper, from open citation data, with Crossref's record of each; the 100 newest when there are more.
References (36)
What it cites, from open citation data, with Crossref's record of each.
Sign in to see 16 more references
A free account opens the rest of the citing papers and references on every paper’s page.