JMIR Nursing · 20 Nov 2026
Safety, Signal Quality, and Patient Satisfaction With Insertable Loop Recorder Implantation by Specialized Electrophysiology Nurses: Prospective Observational Study
Isabel Lillo Rodenash-index 0, Helena Reig Gómez, Raquel Ajo Ferrer, Ángela María Carrillo Molina, María Ajo Ferrer, Sofiane Ghodbane Kiamouche, Juan Gabriel Martínez Martínezh-index 17
Citations by database
Each database indexes a different set of journals, preprints and books, so they are shown side by side rather than blended.
- OpenCitations0
- Crossref0
- Europe PMC0
Citations per year
The current year is still counting.
- 2026 so far0
Abstract
Abstract Background Insertable loop recorders (ILRs) are subcutaneous cardiac monitoring devices used in the diagnosis of arrhythmias and in the etiological investigation of syncope and cryptogenic stroke. Device miniaturization and procedural simplification have facilitated implantation in ambulatory settings. The involvement of specialized electrophysiology nurses may help meet rising clinical demand, although evidence in our setting remains limited. Objective This study aimed to analyze implantation safety, detection signal quality, adverse events during follow-up, and patient satisfaction when the procedure was performed by specialized nurses. Methods This prospective observational study (the CARDIONURSE study) was conducted in the Arrhythmia Unit of Hospital General Universitario Doctor Balmis between February 2022 and May 2023. Thirty-five patients with a clinical indication for ILR implantation were included. The procedure was performed by 2 specialized nurses under medical supervision. Sociodemographic, clinical, and technical implantation variables were collected, including detection signal amplitude (mV), together with adverse events and follow-up outcomes at 1 and 6 months. Patient satisfaction was assessed using a study-specific questionnaire at 4 time points. Descriptive statistical analysis was performed. Results Mean age was 71.1 (SD 11.3) years, and 62.9% (22/35) were women. The most frequent indication was syncope (27/35, 77.1%), followed by suspected atrial fibrillation (AF) in cryptogenic stroke (6/35, 17.1%). No objective procedural complications occurred (35/35, 100% of procedures); mild, transient procedural pain was reported in 5.7% (2/35) of patients, and the procedure lasted less than 5 minutes in 74.3% (26/35) of procedures. Mean signal amplitude was 0.45 (SD 0.29) mV, with a visible P wave in 94.3% (33/35) of patients. No wound-related adverse events were recorded among the 85.7% (30/35) of patients with available follow-up data at 6 months; data were unavailable for the remaining 5 patients. A diagnosis was obtained in 20% (6/30) of patients with an available diagnostic outcome at 6 months. Overall, 97.1% (34/35) of patients reported maximum or very high satisfaction with the intervention, and 100% (35/35) with the care received. Conclusions ILR implantation by specialized electrophysiology nurses in an ambulatory setting is a safe, fast, and technically adequate procedure, with adequate signal quality and high patient satisfaction. These findings support the feasibility of specialized nursing as ILR implanters in similar ambulatory care settings, although confirmation in larger, multicenter studies is warranted before broader implementation.
What the data shows
- No database records a citation yet, as is usual for a paper this new.
- Juan Gabriel Martínez Martínez has the highest h-index among the authors (17).
Graph
This paper in the middle, its authors and their most-cited papers below, the papers it cites to the left and the papers citing it to the right. The timeline lays every paper out by year.
Select a node for its details. Drag to pan, scroll to zoom, drag a node to move it.
Start with
Cited by 0 papers
Who cites this paper, from open citation data, with Crossref's record of each; the 100 newest when there are more.
References (10)
What it cites, from open citation data, with Crossref's record of each.