Frontiers in Digital Health · 11 Nov 2026
Automated breast cancer staging from Chinese-language PET/CT reports using two large language models: a retrospective single-center study
Wan Qi-Chang, Min Kai-Yin, Tang Lei-Lei, Li Wen-Jia, Wang Cheng-Yi, Li Jian-Fang, Ji Bin
Citations by database
Each database indexes a different set of journals, preprints and books, so they are shown side by side rather than blended.
- OpenCitations0
- Crossref0
Citations per year
The current year is still counting.
- 2026 so far0
Abstract
Objective To evaluate the performance of GPT-5.5 Pro and DeepSeek-V4-Pro in automated breast cancer cTNM and AJCC anatomic staging from Chinese-language PET/CT reports. Methods A curated test set of 298 pretreatment 18 F-FDG PET/CT reports from routine clinical practice, obtained between February and December 2025 at our institution, was included. All reports had been verified against the corresponding imaging findings and screened to exclude errors or omissions. Following AJCC 8th-edition cTNM criteria, GPT-5.5 Pro and DeepSeek-V4-Pro assigned cT, cN, cM, and AJCC anatomic stage using a task-specific, rule-guided zero-shot prompt developed using a separate set of 20 reports and locked before final evaluation. Model outputs were compared with an expert report-based reference standard. Performance against this reference standard was assessed using accuracy and macro-averaged precision, recall, and F1 score; agreement was assessed using Cohen's κ. Model errors were categorized as diagnostic reasoning, feature processing, or knowledge application errors. Results For cT staging, GPT-5.5 Pro and DeepSeek-V4-Pro achieved accuracies of 98.3% and 97.0% ( P = 0.39) and macro-F1 scores of 0.968 and 0.952 ( P = 0.51), respectively. For cM staging, the corresponding accuracies were 99.7% and 98.0% ( P = 0.06), and the macro-F1 scores were 0.990 and 0.932 ( P = 0.06). cM1 sensitivity was 96.3% versus 77.8%, with 1 versus 6 missed cM1 cases, respectively. A significant performance difference emerged in cN staging, where GPT-5.5 Pro achieved higher accuracy (97.3% vs. 87.2%, P < 0.001) and macro-F1 score (0.959 vs. 0.729, P < 0.001), resulting in superior overall AJCC anatomic stage classification (accuracy, 98.3% vs. 90.3%; macro-F1, 0.968 vs. 0.861; both P < 0.001). Agreement with the reference standard was almost perfect for GPT-5.5 Pro across all tasks ( κ = 0.96–0.98), whereas κ values for DeepSeek-V4-Pro ranged from 0.80 to 0.95. Across the three component TNM tasks, GPT-5.5 Pro produced 14 classification errors, compared with 53 for DeepSeek-V4-Pro; most errors involved cN staging, and DeepSeek-V4-Pro errors were predominantly classified as knowledge application or diagnostic reasoning errors. Conclusion Both models showed high agreement with the expert report-based reference standard under curated input conditions, with GPT-5.5 Pro showing higher performance for cN and overall AJCC anatomic stage classification.
What the data shows
- No database records a citation yet, as is usual for a paper this new.
Graph
This paper in the middle, its authors and their most-cited papers below, the papers it cites to the left and the papers citing it to the right. The timeline lays every paper out by year.
Select a node for its details. Drag to pan, scroll to zoom, drag a node to move it.
Start with
Cited by 0 papers
Who cites this paper, from open citation data, with Crossref's record of each; the 100 newest when there are more.
References (28)
What it cites, from open citation data, with Crossref's record of each.
Sign in to see 8 more references
A free account opens the rest of the citing papers and references on every paper’s page.