Frontiers in Medicine · 11 Nov 2026
Performance–efficiency trade-offs of large language models for structured extraction from Chinese clinical free text: a benchmark study of model scale, reasoning mode, and architecture
Bosen Hu, Fei Wang, Chengdian Lan, Pan Liu, Ying Yu, Li Zhou, Ning Li, Pengliang Wu, Hua Yang
Citations by database
Each database indexes a different set of journals, preprints and books, so they are shown side by side rather than blended.
- OpenCitations0
- Crossref0
Citations per year
The current year is still counting.
- 2026 so far0
Abstract
Background Large language models (LLMs) may support structured extraction from clinical free text, but evaluation should consider accuracy, output validity, and inference efficiency. Objective To evaluate LLM performance–efficiency trade-offs in Chinese clinical text extraction across model scale, reasoning mode, temperature, architecture, and text-only versus multimodal configurations. Methods This single-center retrospective benchmark sampled 100 Chinese clinical reports per task: left ventricular ejection fraction (LVEF) extraction, carotid intima-media thickness (IMT) extraction, and coronary computed tomography angiography (CTA) classification. The same 300 reports were evaluated under 23 conditions, yielding 6900 outputs. Outcomes included output validity and all-report accuracy (exact-match for LVEF and IMT; classification for CTA). Class-specific precision, recall, and F1, macro-F1, and the Matthews correlation coefficient (MCC) were calculated among valid CTA responses. Local inference efficiency measures included tokens, time to first token, and end-to-end latency. Results Four designated default configurations achieved 99.7% overall accuracy and 100.0% validity. CTA accuracy was 99.0%, with valid-response macro-F1 of 0.984–0.985 and MCC of 0.969–0.970, although false-positive and false-negative errors differed. Reasoning increased Qwen3-0.6B overall accuracy from 31.0% to 88.7% and CTA MCC from 0.025 to 0.599. For Qwen3-32B, overall accuracy increased from 98.7% to 99.7%, CTA MCC from 0.890 to 0.970, and median end-to-end latency from 3.746 to 32.097 s. Temperature changes offered no consistent improvement across CTA metrics. Dense and mixture-of-experts configurations had closely spaced CTA metrics but different latency and token profiles. Text-only and multimodal Qwen configurations showed no consistent relative advantage across two temperatures. The primary dense-only parameter-scale association was not significant after multiplicity correction, and report-level estimates were sensitive to model composition. Conclusions Several evaluated configurations achieved high LVEF and IMT exact-match accuracy, CTA classification performance, and output validity on three predefined tasks. Class-specific metrics identified error differences that accuracy alone did not capture. Selection should consider all-report performance, output validity, class-specific errors, and inference requirements under intended deployment conditions.
What the data shows
- No database records a citation yet, as is usual for a paper this new.
Graph
This paper in the middle, its authors and their most-cited papers below, the papers it cites to the left and the papers citing it to the right. The timeline lays every paper out by year.
Select a node for its details. Drag to pan, scroll to zoom, drag a node to move it.
Start with
Cited by 0 papers
Who cites this paper, from open citation data, with Crossref's record of each; the 100 newest when there are more.
References (16)
What it cites, from open citation data, with Crossref's record of each.