OpenResearchAlpha

Bioengineering · 20 Nov 2026

Prognostic Factors for Visual Outcomes Following Ultrathin Descemet Stripping Automated Endothelial Keratoplasty: A Retrospective Study

Dongyoung Leeh-index 6, Yeo Kyoung Won, Tae-Young Chung, Dong Hui Limh-index 12

0
Citations
no database records one yet
0
Citations in 2026
so far
12
Leading author's h-index
Dong Hui Lim, in QAI's scholar index
20
References
works it cites, from open citation data

Citations by database

Each database indexes a different set of journals, preprints and books, so they are shown side by side rather than blended.

  • OpenCitations0
  • Crossref0

Citations per year

The current year is still counting.

  • 2026 so far0

Abstract

The relationship between donor graft thickness and visual recovery after Descemet stripping automated endothelial keratoplasty (DSAEK) is well recognized, but whether differences in thickness within the ultrathin range affect visual outcomes remains unclear. We retrospectively reviewed 87 ultrathin DSAEK procedures in 79 eyes (graft thickness, 42–100 μm) with at least 6 months of follow-up. Six-month best spectacle-corrected visual acuity (BSCVA), expressed as the logarithm of the minimum angle of resolution (logMAR), was analyzed as a continuous outcome using univariable and multivariable linear regression. An exploratory receiver operating characteristic (ROC) analysis was also performed. Mean logMAR BSCVA improved from 1.44 preoperatively to 0.36 at 6 months. Worse preoperative BSCVA (B = 0.127, p = 0.018) and thicker donor grafts (0.07 logMAR per 10 μm; 95% confidence interval [CI], 0.03–0.10; p < 0.001) were independently associated with worse 6-month visual acuity. Eyes with worse preoperative BSCVA showed greater visual improvement (p < 0.001). Previous glaucoma surgery was not independently associated with visual outcome among eyes whose grafts remained clear for 6 months. The ROC-derived graft-thickness threshold was 68.5 μm (area under the curve [AUC], 0.640). Within the ultrathin range, thinner grafts and better preoperative vision were associated with better 6-month visual outcomes.

What the data shows

  • No database records a citation yet, as is usual for a paper this new.
  • Dong Hui Lim has the highest h-index among the authors (12).

Graph

This paper in the middle, its authors and their most-cited papers below, the papers it cites to the left and the papers citing it to the right. The timeline lays every paper out by year.

Citing paper shares an authorAuthor without a profileSize shows citations, or h-index for authors

Select a node for its details. Drag to pan, scroll to zoom, drag a node to move it.

Start with

Authors (4)

Each author's standing in QAI's scholar index: the works their ORCID iD is attached to, and for anyone whose ORCID record names a lab OpenResearch follows, their arXiv preprints matched by name and a shared co-author. Names are as printed on the paper.

ProfileMost-cited paper

Cited by 0 papers

Who cites this paper, from open citation data, with Crossref's record of each; the 100 newest when there are more.

0 shown
No citing papers for this filter.

References (20)