OpenResearchAlpha

Journal of Clinical Medicine · 12 Nov 2026

Distinguishing Post-LASIK Ablation Patterns on Corneal Tomography: Comparing Clinician Versus Large Language Model

Andrea C. Vazquez-Loretoh-index 1, Sanjana Molleti, Hanna Pawlowski, Calisa G. Lee-Choi, Cole S. Elsner, Mina M. Sitto, Gabriel N. Medina, Niki C. Feiz, Phillip C. Hoopes, Majid Moshirfarh-index 19

0
Citations
no database records one yet
0
Citations in 2026
so far
19
Leading author's h-index
Majid Moshirfar, in QAI's scholar index
16
References
works it cites, from open citation data

Citations by database

Each database indexes a different set of journals, preprints and books, so they are shown side by side rather than blended.

  • OpenCitations0
  • Crossref0

Citations per year

The current year is still counting.

  • 2026 so far0

Abstract

Background: The purpose of this study is to assess the ability of generative AI and a refractive surgeon to distinguish post-LASIK Scheimpflug tomography images based on original excimer laser ablation and to recognize untreated corneas. Methods: Corneal tomography Pentacam images from 204 eyes, which included hyperopic ablations, myopic ablations, myopic astigmatic ablations, mixed astigmatic ablations, or untreated eyes, were compiled. These were individually queried in ChatGPT-5.5 using a multiple-choice prompt to obtain a response. A refractive surgeon was also tested on the same 204 corneas. Results: The clinician obtained higher overall accuracy (85.8% [95% CI 80.2–90.3]) compared to ChatGPT, (60.3% [95% CI 53.2–67.1], p < 0.001) and was significantly more likely to answer correctly overall based on McNemar’s test. Additionally, ChatGPT underperformed in the myopia with astigmatism, mixed astigmatism, and untreated categories, with sensitivities of 38%, 6.3%, and 76%, respectively. Conclusions: The overall accuracy of ChatGPT-5.5 did not meet that of the clinician while ability to identify myopic and hyperopic ablation patterns was comparable. Both the AI model and the clinician had decreased accuracy in myopic astigmatism and mixed astigmatism ablation patterns, though the clinician still performed significantly better. Further studies involving alternative AI models, multicenter data, and standardized evaluation protocols are warranted to establish the clinical applicability of these findings.

What the data shows

  • No database records a citation yet, as is usual for a paper this new.
  • Majid Moshirfar has the highest h-index among the authors (19).

Graph

This paper in the middle, its authors and their most-cited papers below, the papers it cites to the left and the papers citing it to the right. The timeline lays every paper out by year.

Citing paper shares an authorAuthor without a profileSize shows citations, or h-index for authors

Select a node for its details. Drag to pan, scroll to zoom, drag a node to move it.

Start with

Authors (10)

Each author's standing in QAI's scholar index: the works their ORCID iD is attached to, and for anyone whose ORCID record names a lab OpenResearch follows, their arXiv preprints matched by name and a shared co-author. Names are as printed on the paper.

ProfileMost-cited paper

Cited by 0 papers

Who cites this paper, from open citation data, with Crossref's record of each; the 100 newest when there are more.

0 shown
No citing papers for this filter.

References (16)

What it cites, from open citation data, with Crossref's record of each.