OpenResearchAlpha

arXiv · 10 Nov 2026

Quantum-walk transport oracles and amplitude estimation of a scalar range statistic in proton therapy

Kwangzoo Chung

0
Citations
no database records one yet
0
Citations in 2026
so far
–
Leading author's h-index
no author has a profile yet
0
References
works it cites, from open citation data

Citations by database

Each database indexes a different set of journals, preprints and books, so they are shown side by side rather than blended.

  • OpenCitations0

Citations per year

The current year is still counting.

  • 2026 so far0

Abstract

Quantum amplitude estimation (QAE) promises a quadratic reduction in the sampling cost of Monte Carlo (MC) particle transport, but two obstacles have kept it from radiotherapy physics: the lack of an efficient unitary encoding of charged-particle transport, and the mismatch between QAE's single-scalar output and the per-voxel structure of dose calculation. We address both. We construct a discrete-time quantum-walk transport oracle for protons in which an energy register is driven by an energy-dependent coin encoding a continuous-slowing-down surrogate of the stopping power, so that stochastic energy loss and range straggling follow from the circuit dynamics. The oracle is unitary, with one fresh coin qubit per step, and its gate count grows linearly in the number of energy levels. On it we formulate a scalar range statistic, the probability that a proton penetrates beyond a distal depth threshold, as a directly marked amplitude, and estimate it by maximum-likelihood amplitude estimation (MLQAE) with Grover iterations and finite shots. The oracle reproduces a Bragg-shaped depth-deposit profile agreeing with a classical MC of identical rules to within 0.27%, and Grover amplification matches $\sin^2((2k+1)θ)$ to machine precision up to $k=32$. At matched budget the MLQAE error falls as $N^{-0.93}$ against $N^{-0.49}$ for sampling, 4.8 times smaller at the largest budget. A three-gate resource analysis (output structure, amortization, error-corrected wall-clock) finds full dose maps structurally unfavourable irrespective of hardware, and the scalar statistic short of a wall-clock crossover at clinical scale: the oracle's derived cost of $1.0 \times 10^6$ logical gates per call ($3.5 \times 10^7$ with rotation synthesis), dominated by the multiplexed coin, is 160 to 5400 times the permitted budget. We report the reduction that would be required and identify the term responsible for it.

physics.med-phQuantum physics

What the data shows

  • No database records a citation yet, as is usual for a paper this new.

Graph

This paper in the middle, its authors and their most-cited papers below, the papers it cites to the left and the papers citing it to the right. The timeline lays every paper out by year.

Citing paper shares an authorAuthor without a profileSize shows citations, or h-index for authors

Select a node for its details. Drag to pan, scroll to zoom, drag a node to move it.

Start with

Authors (1)

Each author's standing in QAI's scholar index: the works their ORCID iD is attached to, and for anyone whose ORCID record names a lab OpenResearch follows, their arXiv preprints matched by name and a shared co-author. Names are as printed on the paper.

ProfileMost-cited paper

Cited by 0 papers

Who cites this paper, from open citation data, with Crossref's record of each; the 100 newest when there are more.

0 shown
No citing papers for this filter.

References (0)

What it cites, from open citation data, with Crossref's record of each.

No references in the open citation data yet.
Quantum-walk transport oracles and amplitude estimation of a scalar range statistic in proton therapy - QAI OpenResearch