OpenResearchAlpha

arXiv · 19 Nov 2026

Syndrome-based Calibration Using Gate-Error Amplification

Andrew T. Kamen, Arielle Sanford, Frederic T. Chong, Andy J. Goldschmidt, Siddharth Dangwal

0
Citations
no database records one yet
0
Citations in 2026
so far
–
Leading author's h-index
no author has a profile yet
0
References
works it cites, from open citation data

Citations by database

Each database indexes a different set of journals, preprints and books, so they are shown side by side rather than blended.

  • OpenCitations0

Citations per year

The current year is still counting.

  • 2026 so far0

Abstract

We present Gate-Error Amplification for Recalibration with Syndromes (GEARS), a runtime calibration framework that uses gate-error amplification to efficiently tune control parameters during quantum error correction. Maintaining reliable control of large qubit arrays throughout hours-long computations requires repeated calibration to compensate for hardware drift. In conventional calibration, targeted qubits are temporarily removed from the code, introducing non-negligible space-time overhead. An elegant alternative uses syndrome information already collected during error correction as feedback for in situ recalibration, but acquiring signal requires sufficient (1) measurement budget or (2) probe strength, i.e., the size of deliberate control perturbations. More measurements improve statistical precision but result in slower control updates, while stronger perturbations produce larger calibration signals at the cost of additional errors. GEARS augments syndrome-based calibration with an established gate characterization technique called gate-error amplification. Our approach repeats selected CZ gates and probes their controls in spatially separated groups, strengthening local calibration signals while limiting the logical cost of probing. Surface code simulations show that GEARS with depth-three amplification reduces measurement requirements by approximately a factor of eight at matched gradient SNR and fixed probe strength. In closed-loop calibration, GEARS with depth-three amplification reduces excess expected logical failures by approximately 31-40% relative to calibration without amplification across the evaluated execution windows. Under time-dependent drift, GEARS increases the estimated critical drift frequency by approximately 1.9x. These results indicate that deliberately amplifying gate errors during operation can improve the long-time performance of quantum computations.

Quantum physics

What the data shows

  • No database records a citation yet, as is usual for a paper this new.

Graph

This paper in the middle, its authors and their most-cited papers below, the papers it cites to the left and the papers citing it to the right. The timeline lays every paper out by year.

Citing paper shares an authorAuthor without a profileSize shows citations, or h-index for authors

Select a node for its details. Drag to pan, scroll to zoom, drag a node to move it.

Start with

Authors (5)

Each author's standing in QAI's scholar index: the works their ORCID iD is attached to, and for anyone whose ORCID record names a lab OpenResearch follows, their arXiv preprints matched by name and a shared co-author. Names are as printed on the paper.

ProfileMost-cited paper

Cited by 0 papers

Who cites this paper, from open citation data, with Crossref's record of each; the 100 newest when there are more.

0 shown
No citing papers for this filter.

References (0)

What it cites, from open citation data, with Crossref's record of each.

No references in the open citation data yet.