OpenResearchAlpha

bioRxiv · 3 Nov 2026

Noise-referenced multi-shell diffusion-weighted imaging for regional cerebrospinal fluid thermometry

C. Behler, M. Breakspear, S. Ramadan, T. T. Dao, T. G. Close, S. B. Vos, R. Thienel, J. Giorgio, A. Behler, M. Fay

0
Citations
no database records one yet
0
Citations in 2026
so far
–
Leading author's h-index
no author has a profile yet
0
References
works it cites, from open citation data

Citations by database

Each database indexes a different set of journals, preprints and books, so they are shown side by side rather than blended.

  • OpenCitations0

Citations per year

The current year is still counting.

  • 2026 so far0

Abstract

We developed a multi-shell diffusion-weighted imaging approach for separate ventricular and subarachnoid cerebrospinal fluid thermometry. The approach uses measured image noise to assess agreement among temperature estimates. In 12 participants, temperature was estimated from four non-zero diffusion weightings. For each voxel, disagreement between these estimates was compared with that expected from image noise, accounting for their shared reference image. Voxels meeting this consistency criterion were retained for regional analysis. Mean diffusion-derived temperature ({+/-} SD) was 38.4 {+/-} 0.4 {degrees}C in the lateral ventricles and 36.0 {+/-} 1.1 {degrees}C in the subarachnoid space. Ventricular estimates were consistently higher than subarachnoid estimates across all participants, with a mean difference of 2.4 {+/-} 1.2 {degrees}C (95% confidence interval 1.6 -3.1 {degrees}C). This difference persisted under alternative noise models and temperature estimators. Subarachnoid estimates increased with retained voxel count; in a post hoc analysis of the six participants with the largest retained counts, ventricular estimates remained higher by 1.6 {+/-} 0.7 {degrees}C. Absolute temperature accuracy and the physiological origin of the regional difference require independent validation. This approach provides an internal consistency check for CSF thermometry and supports separate assessment of ventricular and subarachnoid temperatures.

Neuroscience

What the data shows

  • No database records a citation yet, as is usual for a paper this new.

Graph

This paper in the middle, its authors and their most-cited papers below, the papers it cites to the left and the papers citing it to the right. The timeline lays every paper out by year.

Citing paper shares an authorAuthor without a profileSize shows citations, or h-index for authors

Select a node for its details. Drag to pan, scroll to zoom, drag a node to move it.

Start with

Authors (10)

Each author's standing in QAI's scholar index: the works their ORCID iD is attached to, and for anyone whose ORCID record names a lab OpenResearch follows, their arXiv preprints matched by name and a shared co-author. Names are as printed on the paper.

ProfileMost-cited paper

Cited by 0 papers

Who cites this paper, from open citation data, with Crossref's record of each; the 100 newest when there are more.

0 shown
No citing papers for this filter.

References (0)

What it cites, from open citation data, with Crossref's record of each.

No references in the open citation data yet.
Noise-referenced multi-shell diffusion-weighted imaging for regional cerebrospinal fluid thermometry - QAI OpenResearch