OpenResearchAlpha

bioRxiv · 12 Nov 2026

Volumetric Cross-Amplitude Modulation (VxAM) for Transcranial Gas Vesicle Imaging

Andrew S Weitzh-index 2, Hatim Belgharbi, Masashi Sode, Rebecca M Jones-Sinnott, Rohit Nayak, Trevor Fochtman, Mikhail G. Shapiro, Paul A Dayton, Gianmarco F Pinton

0
Citations
no database records one yet
0
Citations in 2026
so far
2
Leading author's h-index
Andrew S Weitz, in QAI's scholar index
0
References
works it cites, from open citation data

Citations by database

Each database indexes a different set of journals, preprints and books, so they are shown side by side rather than blended.

  • OpenCitations0
  • Crossref0

Citations per year

The current year is still counting.

  • 2026 so far0

Abstract

Cross-amplitude modulation (xAM) is a commonly used pulse sequence for non-destructive, quasi-artifact-free detection of gas-vesicle (GV) contrast agents, but it has so far been limited to two-dimensional cross-sections acquired with one-dimensional linear arrays. We present the first implementation of xAM on a fully sampled two-dimensional matrix array, extending the half-aperture split of conventional xAM to a family of 2D sub-aperture partitions on a 32x32-element Vermon probe (7.81 MHz, 300 μm element pitch). Angular spectrum simulations compared three primary bisections (X-axis, Y-axis, and diagonal (D1,D2)), and the selected Y-split was tested experimentally in GV-loaded tissue-mimicking phantoms. We also simulated an electronic asymmetric-angle sweep as an alternative to the robotic translation used in the experiments, and measured contrast through an ex vivo mouse skull. The non-emissive regions between the elevation panels of the Vermon probe accounted for most of the simulated differences among partitions, through both the continuity of the aperture parallel to the bisector plane and the side-lobe structure. At a 6 degree steering angle, the Y-split gave a contrast-to-tissue ratio (CTR) of ~29 dB for single frames and ~49 dB with 100-frame averaging without the skull, and a contrast-to-noise ratio (CNR) of ~8 dB for single frames and ~12 dB with 100-frame averaging through the skull, where the inclusion remained resolvable. These results give design rules for xAM on matrix arrays. The through-skull result comes from a single ex vivo specimen, and in vivo work is the next step toward non-invasive, longitudinal, three-dimensional monitoring of GV-labeled glioblastoma and other targets of nonlinear contrast agents.

Bioengineering

What the data shows

  • No database records a citation yet, as is usual for a paper this new.
  • Andrew S Weitz has the highest h-index among the authors (2).

Graph

This paper in the middle, its authors and their most-cited papers below, the papers it cites to the left and the papers citing it to the right. The timeline lays every paper out by year.

Citing paper shares an authorAuthor without a profileSize shows citations, or h-index for authors

Select a node for its details. Drag to pan, scroll to zoom, drag a node to move it.

Start with

Authors (9)

Each author's standing in QAI's scholar index: the works their ORCID iD is attached to, and for anyone whose ORCID record names a lab OpenResearch follows, their arXiv preprints matched by name and a shared co-author. Names are as printed on the paper.

ProfileMost-cited paper

Cited by 0 papers

Who cites this paper, from open citation data, with Crossref's record of each; the 100 newest when there are more.

0 shown
No citing papers for this filter.

References (0)

What it cites, from open citation data, with Crossref's record of each.

No references in the open citation data yet.